{"product_id":"victron-inverter-12-800-120v-ve-direct-nema-gfci-pin121800510","title":"Victron Inverter 12\/800 120V VE.Direct NEMA GFCI [PIN121800510]","description":"\u003cmeta charset=\"UTF-8\"\u003e\u003cstrong\u003eThe VE.Direct port can be connected to:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eA computer (VE.Direct to USB interface cable needed)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eApple and Android smartphones, tablets, MacBook’s and other devices (VE.Direct Bluetooth Smart dongle needed)\u003c\/li\u003e\n\u003c\/ul\u003e\n \u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eFully configurable:\u003c\/strong\u003e \u003cbr data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLow battery voltage alarm trip and reset levels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLow battery voltage cut-off and restart levels\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDynamic cut-off: load dependent cut-off level\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOutput voltage 210 - 245V\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFrequency 50 Hz or 60 Hz\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eECO mode on\/off and ECO mode sense level\u003c\/li\u003e\n\u003c\/ul\u003e\n \u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eMonitoring:\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIn- and output voltage, % load and alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003e\u003cb\u003eProven reliability:\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003eThe full bridge plus toroidal transformer topology has proven its reliability over many years. \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe inverters are short circuit proof and protected against overheating, whether due to overload or \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003ehigh ambient temperature.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003e\u003cb\u003eHigh start-up power:\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003eNeeded to start loads such as power converters for LED lamps, halogen lamps or electric tools.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003e\u003cb\u003eECO mode:\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003eWhen in ECO mode, the inverter will switch to standby when the load decreases below a preset \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003evalue (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable, \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003edefault: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003e\u003cb\u003eRemote on\/off:\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003eA remote on\/off switch can be connected to a two-pole connector, or between battery plus and the \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eleft-hand contact of the two-pole connector.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003e\u003cb\u003eLED diagnosis:\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003ePlease see manual for a description.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003e\u003cb\u003eTo transfer the load to another AC source: the automatic transfer switch:\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cspan color=\"#333333\" style=\"color: #333333;\" data-mce-style=\"color: #333333;\"\u003eFor our low power inverters, we recommend our Filax Automatic Transfer Switch. The Filax features \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003ea very short switchover time (less than 20 milliseconds) so that computers and other electronic \u003c\/span\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eequipment will continue to operate without disruption.\u003c\/span\u003e\u003cbr\u003e","brand":"Sequence Engineering","offers":[{"title":"Default Title","offer_id":47272348090506,"sku":"PIN121800510","price":258.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/2168\/4874\/files\/PIN121800510_Front_1200x_81f7b6a2-28c6-4663-b63f-89dddd544b4b.jpg?v=1762473434","url":"https:\/\/offgridadventuresystems.com\/products\/victron-inverter-12-800-120v-ve-direct-nema-gfci-pin121800510","provider":"Offgrid Adventure Systems","version":"1.0","type":"link"}